In continuous production scenarios within industrial facilities, the stability and maintainability of the power distribution system directly impact operational efficiency. Conventional fixed-type switchgear requires a complete power shutdown during circuit maintenance, which can easily lead to production line interruptions. Addressing this pain point, the GCK low-voltage withdrawable switchgear, with its modular withdrawable structure and a range of targeted configurations, offers an industrial power distribution solution that allows maintenance without halting other circuits.
The GCK switchgear adopts a withdrawable design. The drawer and circuit breaker are equipped with a mechanical interlock, ensuring that the drawer can be independently withdrawn for maintenance only after the corresponding circuit breaker is disconnected, without affecting the normal power supply of other circuits. This structural design reduces the risk of production stoppages due to maintenance. Drawer units of the same specification are fully interchangeable. When a fault occurs in a particular circuit, a spare drawer can be directly used as a replacement, eliminating the need for on-site disassembly and repair and significantly shortening fault handling time. Additionally, each drawer features three operating positions: connected, test, and disconnected. The test position allows commissioning and preparation with the main circuit disconnected, without interfering with other operating circuits, while also greatly enhancing safety during maintenance.
From a structural perspective, the GCK switchgear is rigorously designed in accordance with IEC 61439-2 and GB/T 7251.12 standards. The enclosure is assembled using C-section profiles in a modular, dimensionally coordinated manner, offering a compact structure and high versatility. The interior is clearly divided into separate compartments for functional units, busbars, and cables. These compartments are isolated from one another, effectively preventing fault propagation and ensuring both routine protection and operational safety.
Core Technical Parameters – Tianan GCK Low-Voltage Withdrawable Switchgear
| Parameter | Value |
Technical advantage |
|---|---|---|
| Rated operational voltage | AC 380/400/690 V (configured per project requirements) |
Adapts to standard industrial low-voltage grids; high versatility |
| Rated insulation voltage | AC 690/1000 V | High insulation level reduces leakage and breakdown risks |
| Horizontal busbar rated current | Up to 5000 A |
Meets high-power equipment and multi-line centralized power supply (Note 1) |
| Vertical busbar rated current | Up to 1600 A |
Stable branch circuit supply; supports simultaneous loading of multiple circuits |
| Horizontal busbar short-time withstand current (1s) | 20/50/80/100 kA |
Strong anti-short-circuit capability protects busbars from damage under fault conditions |
| Vertical busbar short-time withstand current (1s) | 20/50/65 kA | Reliable branch circuit short-circuit withstand prevents fault escalation |
| Enclosure protection rating | IP30 / IP40 / IP42 | Suited for demanding industrial environments (Note 2) |
Note 1: The maximum horizontal busbar rated current is influenced by enclosure dimensions, cable entry/exit methods, and ambient temperature. Actual capacity should be verified through engineering calculations.
Note 2: IP42 provides protection against dripping water at an angle of up to 15° from vertical, and is not suitable for water spray or rain exposure.
Today, Tianan GCK low-voltage withdrawable switchgear is widely used in power plants, substations, industrial and mining enterprises, airports, terminals, and other settings, providing safe, stable low-voltage power distribution that supports other circuits remaining in operation.
Contact Person: Ms. Lian Huanhuan
Tel: +86-13858385873
Fax: 86-574-87911400