Product Details:
Payment & Shipping Terms:
|
Altitude: | Up To 3, 000m Above Sea Level | Environment: | Outdoor |
---|---|---|---|
Busbar: | 3-Phase And 4-Wire | Frequency: | 50Hz |
Form: | All- Packaged Type | Size: | 3 Units |
High Light: | middle voltage switchgear,gis gas insulated switchgear |
Mid Mounted AC Power Electric Switchgear / Middle Voltage Switchgear 1E Class KYN44A-12
Overviews
IE class KYN44A Metal-clad Mid-mounted AC switchgear (hereinafter called as “switchgear”) designed by Ningbo Tianan (Group) Co., Ltd is a 3~10kV three phase AC 50 Hz distribution device of single busbar and its sectional system. It is the basic constitution unit of 1E class MV electric power system of nuclear power plant. It will be used in executing emergency shut-down, reactor core cooling containment and reactor radiating by nuclear power plant, or preventing radioactive substance obvious leakage function or supporting function. The switchgear meets IEC298, GB3906, GB13625, IEEE649, IEEE344, HAF003, etc. It can prevent pushing and pulling circuit breaker handcart on load, opening circuit breaker incorrectly, making circuit breaker when earthing switch is close, straying live bay and preventing divide the breaker and earthing switch interlocked function.
It is fitted with VEP vacuum circuit breaker and VEC vacuum contactor from Xiamen Huadian Switchgear Co., Ltd, and is a distribution unit with superior performance.
Features
a. 1E class KYN44A switchgear is a kind of small metal –clad air insulated switchgear, it can save space effectively.
b. 1E class KYN 44A switchgear is complete in variety, equipment parameters are up to rated current 3150A, rated short circuit breaking current 50KA.
c. 1E class KYN44A switchgear is safety, reliable and comprehensive in use.
d. 1E class KYN 44A switchgear is designed to mid-mounted type, and fitted with VEP indoor MV closed type vacuum circuit breaker or VEC vacuum contactor-fuse combined unit.
e. 1Eclass KYN44A switchgear has plenty cable connection space.
f. 1Eclass KYN44A switchgear has perfect and reliable five-prevention blocking device.
g. 1E class KYN 44A switchgear can operate and maintain in the front of switchgear, and install against the wall.
h. 1E class KYN44A switchgear is provided with earthing switch short circuit making capacity speediness closing.
i. 1E class KYN44A switchgear and handcart have reliable earthing unit.
Parameters
Height H(mm) |
2250 |
|
---|---|---|
Width (mm) | Vacuum Contactor(F-C) | 325 |
Rated Branch Busbar Current 1250A and Thermal Stability Current 50KA and Below | 800 | |
Rated Branch Busbar Current 1600A and the Above | 1000 | |
Depth (mm) | Cable Incoming and Outgoing Line | 1400 |
Overhead Incoming and Outgoing Line | 1600 | |
Weight (kg) | Vacuum Contactor (F-C) | 300 |
Other Switchgears | 800-1200 |
Contact Person: Ms. Lian Huanhuan
Tel: +86-13858385873
Fax: 86-574-87911400