Product Details:
Place of Origin: CHINA
Brand Name: TIANAN
Certification: CCC, ISO9001
Model Number: ZBW1-12
Payment & Shipping Terms:
Minimum Order Quantity: 1unit
Price: US $20,000-40,000/ Piece
Packaging Details: Nude
Delivery Time: 60days
Payment Terms: L/C, T/T
Supply Ability: 5000 Sets/ Year
Detailed Product Description
Voltage: 12KV/400v Capacity: 30~2000
Breaking Current Of Fuse: 31.5/40 Rated Current Of Main Circuit: 100-4000A
High Light:

oil immersed distribution transformer

,

packaged transformer substation

11kV Outdoor Compact Substation Integrated Substation Packaged Substation RMU IP4X

Product Description

Summarize
ZBW1-12 series Packaged substation is a kind of integrated complete power transmission and distribution equipiment, used in 6-12kV, AC 50Hz power tranmission and distribution system with a transfromer of rated capacity of 30-2500kVA. It is widely used in out-door power supply fields such as high buildings, residentail zone, factory and mining , hotel, park, oil field, airport, wharf, railway, shopping store and other temporary facilities. This product can be used not only in a ring net fro power distribution but also can serve as terminal power supply for power transmiission line.

Features
ZBW1-12 series package substation consists of three parts: transformer room, high voltage room and low voltage room.
1. High voltage sides is equipped with HXGN series RMU (aerogenesis type, compressed air type, vacuum type or SF6 type), equipped with LBS, fuse inside (CB could be equipped, if required).
2. LV side adopts new type ACB, with high breaking capacity and good protection capacity.
3. Transformer room adopts oil immersed type or dry type transformer.
4. Caries materials can be used as enclosure materials, such as aluminum alloy plate, steel pate, compound plate, etc. Roof is double layered, protecting against heat radiation.
5. Inside, there are cooling equipment and anti-comdensation equipment.

Technical Data
  Items Unit Parameters
High Voltage Part Rated voltage kV 12
Rated frequency Hz 50
Rated current of main busbar A 630
1mm power frequency withstand voltage (to earth and between phases/disconnecting fracture) kV 42/48
Lightning impulse withstand voltage (to earth and between phases/disconnecting fracture) kV 75/85
Rated short time withstand current kA/s 25/2
Rated peak withstand current kA 63
Rated short time making current kA 50
Rated transfer current A 1500
Breaking current of fuse kA 31.5 40
Low Voltage Part Rated voltage V 400
Rated current of main circuit A 100-4000
Rated limiting short circuit breaking ability kA 80
Rated operating short circuit breaking ability kA 50 (65)
Rated short time withstand current kA/1s 50 (65)
Branch current,compensating capacity According to requirements of users
Transformer Rated capacity kVA 30-2000
Impedance voltage % 4 4.5
Tapping range % ±2×2.5 ±5
Connection symbol Y, yn0 D, yn11
Case Protection level of enclosure IP23
Sound level dB ≤50