Product Details:
Payment & Shipping Terms:
|
Breaking Time: | 18~45 S | Mechanical Life: | CB:10000 Times Disconnector:2000 Times |
---|---|---|---|
Rated Volatge: | 12/24kV | Circuit Breaker Circuit Resistance: | <80 μΩ |
Contact Closing Bounce Time: | ≤3 Ms | Closing Time: | 25~60 S |
Rated Short Circuit Breaking Current: | 20/25 KA | Three Phase Opening And Closing Asynchrony: | ≤2 Ms |
ZW32 type outdoor pole mounted high-voltage vacuum circuit breaker is an outdoor high-voltage switchgear with a rated voltage of 12/24kV and three-phase AC 50HZ. It is mainly used for breaking and closing load current and short-circuit current of power systems, and is suitable for protection and control in substations, industrial and mining enterprises, and urban and rural distribution networks. It is particularly suitable for frequent operation places and urban and rural distribution automation.
Product Attribute | Value |
---|---|
Product Name | High Voltage Vacuum Circuit Breaker |
Rated Power of Energy Storage Motor | 40/70 W |
Contact Closing Bounce Time | ≤3 Ms |
Rated Peak Withstand Current (Peak) | 50/63 KA |
Rated Current | 630/1250 A |
Circuit Breaker Circuit Resistance | <80 μΩ |
Rated Voltage | 12/24kV |
Closing Time | 25~60 S |
Three Phase Opening and Closing Asynchrony | ≤2 Ms |
Mechanical Life | CB:10000 Times Disconnector:2000 Times |
Breaking Time | 18~45 S |
ZW32 port type circuit breaker is mainly composed of solid sealed integrated pole, current transformer, spring operated mechanism, and base. The spring operating mechanism and pole are fixed on the base, and the sealing structure between the integrated sealing pole, current transformer, and spring operating mechanism is suitable for outdoor environments. It has a compact and elegant design, a simple and clear structure, easy installation, and can meet the requirements of arc extinguishing chamber opening distance and overtravel without adjustment during installation. This type of circuit breaker also reserves auxiliary switch contacts, which can fully meet the different needs of users.
1. Pole pillar 2. Current Transformer 3. Institutional box 4. Spring operated mechanism 5. Terminal box
1 Due to its special design structure, the circuit breaker on this column can ensure long-term maintenance free use for users. It is recommended that users conduct a power frequency withstand voltage test every three years or so, and regularly clean the insulation parts of the circuit breaker according to the local environmental pollution level.
2 Users are not allowed to replace or use electrical components that are inconsistent with the original model specifications at will.
3 Operators should understand the performance, installation, adjustment, and maintenance knowledge of the mechanism, record any problems encountered during operation, and notify the manufacturer if necessary.